HexaDuct is a complete CAD solution for HVAC system Design. It has an innovative way of creating HVAC Ducting network (Ductwork) from simple line network.

This HVAC Software is also a good tool for HVAC project managers due to its in built Document manager and capability to handle multiple files in a project.

With its ability to create impressive walkthrough in and around 3D solid Model of HVAC system, one can visualize the actual HVAC system in advance and can figure out any possible problems or interference which can not be detected in 2D drawings.

This HVAC Software has many ready to use reports like BOM, Acoustic material required, Thermal Insulation required, Total area of sheet metal required for ducting etc.

With very little efforts, you will calculate and design HVAC system and produce ductwork and piping plans of outstanding quality ready for construction and fabrication

HexaDUCT has many advantages over other HVAC system design tools      Know more about it...

Go Top

 
Features

HexaDuct library of HVAC components


Duct routing                     Demo


Power Tools


Cross Section


Reports


Editing Tools


Piping Designing Facilities



Go Top

 

HexaDuct library of HVAC components

HexaDUCT offers wide range of heating and air conditioning (HVAC) components in 2D as well as in 3D Model Format. Due to its Object Oriented approach every HVAC component has its own properties and Model defination script. Model defination script uses rule based scripting language. This makes HexaDUCT possible to generate 3D as well as 2D Model of the object. Properties of all HVAC components are defined in the back end database. Every HVAC Component from the library is generated on the fly. The advantage is that if any property of the HVAC component is changed, its reflected in its graphical appearance.

  • Diffusers (Rectangular, Round) - New Models can be added in the back end database
  • Grille, Slot Diffusers, cassettes - New Models can be added in the back end database
  • Main Unit with Trap Door - Additional models can be added in the back end database
  • Elbow - Both ends can be of different size as well as shape
  • S Bend - Round as well as Rectangular
  • Concentric and Eccentric Reducer - Both ends can be of different shape
  • Ducts - Round as well as Rectangular
  • plenum - Calculate plenum size before placing it in the drawing
  • Tee - outlet1 and outlet2 can be of different size as well as shape with respect to inlet
  • Cross - outlet1, outlet2 and outlet3 can be of different size as well as shape with respect to  inlet
  • Collar - Round as well as Rectangular
  • Dampers
  • Tail End
  • Flexible Duct
HVAC Components underlined can have optional acoustic or thermal lining (Internal or external)

Go Top


Duct Routing

Designing of Duct Routing is an important phase of heating and air conditioning (HVAC) system.
There are many factors which directly affects the performance of heating and air conditioning (HVAC) system. Undersized Ducts, Improper selection of duct material, Improper selection of matal sheet thickness, Too high or too low design velocity, Unnecessary use of sharp bends or excessive bends in duct work, Improper acoustic or thermal insulation,etc

With the help of HexaDuct tools duct routing work becomes easy and less error prone. Due to HexaDUCTs object oriented architecture, CAD knowledge is NOT mandatory.
Using simple steps shown below HVAC Duct Routing can be accomplished

  • Place diffusers, main Units and/or plenum.
  • Join diffusers with plenum or main unit using routing lines         Learn more about it...
  • Run Ducting Tool to generate ducting from routing lines         Learn more about it...
  • Use Power tools to accomplish various tasks
  • Use Cross Section, and reporting tools.
  • Go Top


    Power Tools

    Power tools simplifies the complex work of HVAC Ducting and its Modification,
    Various HexaDUCT Power tools are listed below

  • Concentric to Eccentric :When the HVAC ducting is running along side a wall, it is necessary to make the side facing to the wall to be aligned with that wall. All concentric Tee's, Reducer's needs to be changed to eccentric form. The ducting also needs to be shifted. The complexity increases if branching is done in theses segments. Concentric to Eccentric tool does this job in one go. User needs to select the TEE or Reducer and entire ducting after its outlet1 including the branching if any will get adjusted.              Show me How to do it...

  • Replace Tee with Collar :There are two common ways to take out the branching from the main Duct. By placing a TEE and taking out branch, or by connecting branch to main duct by collar. Many times we also need to replace a TEE with Collar and Reducer pair. Replace Tee with Collar tool is a handy tool which simplifies this job. User can select a TEE to get it replaced by collar-Reducer pair or select main duct and branching duct to join them by collar. Branching Duct is stretched or trimmed if required.                      Show me How to do it...

  • Network Lining :It is often required to insulate the ducting for either Heat Loss (Thermal lining) or to reduce the noise level (Acoustic lining). Noise level is highest at the Fan End, therefore normally Acoustic lining is required at Fan End, while heat loss precaution needs to be taken at the far end of ducting. Network Lining tool makes things simpler by traversing network and adding lining whereever required. Specify the percentage covarage to be done of the total ducting run length and tool does its job                          Show me How to do it...

  • Change Size :It is often required to change the duct size (width or height) due to external constraints. While changing the size (width or height) it is important to maintain the cross sectional area of duct. At the same time user also needs to modify the adjoining components sizes to match ends. Change Size tool takes care of both issues and gives flexibility of either changing width or height of the duct.                           Show me How to do it...

  • Place Tail End :HVAC Duct detailing work depends on for what purpose the drawing is to be used. If the drawing is for fabrication purpose or for realistic modeling, it is necessary that all open ends of the ducts to be shown closed using END CAP. Place Tail End tool helps user to close open ends of all ducts with minimum effort. This tool also extends its capabilities to close the end and take out the branching if required                                                                                                                                                           Show me How to do it...

  • Dimensioning :Dimensioning is one of the important aspect of any finished drawing. Length, width and height values are the minimum requirements of duct dimensioning. Sometimes it is also necessary to mention the BOD length when different ducts are running at different elevations, Some experts also follow the practice of specifying the shape of duct and air quantity (CFM). Duct Dimensioning tool is designed to tackle all these issues. Apart from L X W X H this tool also allows to specify air Quantity (CFM), shape of duct and BOD.                                                                                                                                                           Show me How to do it...

  • acoustic Lining :If an HVAC System is properly designed and installed using good quality components, its operation will be extremely quiet. To ensure optimum noise control it is required to add acoustic lining to components. Depending on the surroundings acoustic lining can be internal or external. Some times partial lining of ducts is also needed. Acoustic Lining tool also allows you to insulate ducts in between two ends

  • Thermal Insulation :The rapidly escalating cost of fuel has made everyone aware of energy conservation. The need for better thermal insulation evolved from this background.
    'Thermal Insulation' tool adds Thermal Insulation to components. Insulation can be of internal or external type. In case of duct partial Insulation is also possible.

  • Place Main Tee :Replaces Normal Tee with Main Duct Tee.

  • Ductulator :Computer version of standard ductulator which can be used to set the size of the duct.
  • Go Top


    Cross Section                                                                                Show Me How to do it...

    A cross-sectional view portrays portion of the HVAC Ducting network when viewed from direction other than top view. These views are especially helpful when the ducting elevation is changing which is not visible in Top view.
    'Generate cross section' tool redraws ducting when looked from the direction of cross sectional arrow.
    Procedure is very simple. Place Cross sectional arrow facing the direction from where the cross section needs to be generated. Select Cross Sectional Arrow and the components from HVAC ducting network that should appear in the cross sectional view.

    Go Top


    Reports

    HexaDuct offers various ready to use reports covering all your needs.

  • Components List
  • Duct List
  • Main Unit List
  • Diffuser List
  • Costing Report
  • acoustic lining report for all components
  • acoustic lining report for ducts
  • Thermal lining report for all components
  • Thermal lining report for ducts

  • Reports can be directly placed on drawing as a table or can be exported to MS Excel & PDF Format.

    Go Top


    Editing Tools


  • Flip ‘X’ and Flip ’Y’

  • Objects can be flipped dynamically while placing or editing.
  • Join

  • Joins two routing lines or ducts.
  • Cut Back

  • If user place or move component like reducer over a duct, it cuts back the duct.
  • Slide

  • User can "slide" a component over a duct, place it on the Duct or Pipe as per command bar or dynamically.
  • Stretch

  • Ducts, Routing lines or Pipeline can be stretched keeping reducers, Branches (Tees) and other inline components over it intact.
  • Delete

  • You can "delete" a reducer or any other component and the ducts on either sides will get connected automatically.
  • Modify properties

  • user can change the properties of components.Changing the size of a duct will also change the respective sizes of nebouring components to match the ends
  • Match Properties

  • User can apply properties of one component to that of another component (such as: Length, Width, Height, Colour etc)

    Go Top


    Piping Tools

  • Machine CKT
  • Pipe Sizes (Liquid & Gas)
  • Color based Indoor Piping
  • Color based Outdoor Piping
  • Piping Routing
  • Pressure Losses in Piping System
  • Insulation Material Selection
  • Go Top


    Training

    HexaDUCT is very easy to use and hence has a minimum learning curve. Apart from this, one can learn hexaDUCT by reading User Manuals (.chm) or by running small interactive audio-visual demo files.

    Download HexaCAD (Basic CAD) User Manual

    Download HexaDUCT (HVAC) User Manual

    Download Tutorials

    • Connecting Diffusers to Main Unit using routing lines

    Go Top

    Hvac Ducting Software , HVAC , hvac software , AutoCAD, hexacad , engineering , architecture , HVAC , hvac software, AutoCAD , air duct , engineering , architecture , CAD , computerized automated design , heating ventilating air conditioning software , hexacad , contractor , architect , HVAC , hvac software , AutoCAD , air duct , engineering , architecture , CAD , computerized automated design , heating ventilating air conditioning software , hexacad contractor , architect , HVAC , hvac software , AutoCAD , air duct , engineering , architecture , CAD , computerized automated design heating ventilating air conditioning software , hexacad , contractor , architect , AEC AEC A/E/C A/E/C AEC AEC A/E/C A/E/C , 2 way control, 3 way control, ACCA, ACCA approved, ACCA manual d, ACCA manual j, ACCA manual n, ACGIH, ACSR, ACSR cable, AE, AEC, A/E/C AE firm, AGA, air conditioner, air conditioning, air conditioning contractors, air conditioning contractors association, air conditioning design, air conditioning software, air handler, air source heat pump, air space resistance, air system, Akton, American Gas Association, ammonia, analysis, APEC, appliance, appliance analysis, appliance operating cost, architect, ARI, ARI database, Armstrong, ASHRAE, ASHRAE Standard 62, ASPE, AUDIT, Autocad, Autodesk, automated, automatic peaking, automation, bin data, bin weather data, blast gate, blast to outlet, backflow preventer, balance point, bid, bill disaggregation, bill of materials, Bill Smith, Bill Wright, bin, bin analysis, blast to outlet area ratio, blower, blower door, BOCA, BOCA Code, BOHN, boiler, branch, Bryan, Bryant, building design, building energy analysis, building envelope, building loads, building operating costs, Bussmann, CAD, CADD, CALA, calculations, capacitor, capacity, CAPTOR, carbon monoxide, carbon monoxide poisoning, Carmelsoft, Carrier, Carrier Air Conditioning, Carrier Resource, category 1, category 1 appliance, cfm, chilled and hot water, chilled water, chilled water analysis, chilled water system, chilled water system simulation, chillers, Chris Jennings, CHVAC, circuit breaker, CLGS, Climate Master, CLTD, coefficient of utilization, coil, coil interpolation, collector, College Station, commercial, commercial hvac load calculations, compressor, computer, computerized, condensing unit, conductor, conductor sizing, constant speed pump, constant velocity, constant volume, consulting engineer, contracting firm, contractor, control valves, cooling, cooling coil, cooling loads, COP, cost analysis, cost comparison, current transformer, custom proposal, custom reports, DAMPER, dehumidification, demand load, demand load supply, design, design foot candles, design method, design/build, development, direct water temperature control, DOE2, DOE2.1, DOE2.1d, DOE2.1e, domestic, domestic hot water, DPIPE, drain, drainage, drainage diffuser sizing, duct, duct attenuation, duct sizing, duct work, ductlink, DUCTSIZE, Duct Size, ductsizing, ductwork, dxf, dxf file, earth coupled, earth coupled analysis, earth coupled diffuser sizing, ECA, ECOORD, EDS, EER, efficiency, electric utility rates, ineering, hexacad Software, hexacad Software Development, hexacad Software Development, energy, energy analysis, Energy Design Systems, engineer, engineering, Engineered Software, engineering design software, engineering software, entering coil, entering coil conditions, entry loss, equal friction, equipment, equipment selection, equivalent length, estimation, ETA, evap coil, evaporator, evaporator coil, exhaust, exhaust ventilation, EZ-DOE, EZDOE, fan, fan curve, fan curve analysis, fan library, fitting, fitting equivalent length, fittings, Fla-Res, flat oval, flexible liner, Florida Heat Pump, flow control, flow control valves, flue, flue diffuser, flue sizing, flue vent, foot candle, foot candles, fresh air, fuel cost, fume hood, furnace, furnace selection, fuse, fuse and breaker, fuse and breaker coordination, GAMA, GAMA database, gas cooling, gas engine heat pump, gas pipe sizing, gas research institute, gas utility rates, gas vent sizing, GASVENT, GE, GE Industrial Power Systems Data, generator, Genesis, glass, glass shading, glass shading analysis, Gould, Gould Shawmut, gpm, gpm flow, GRI, grid, grid builder, grid system, ground fault, ground fault analysis, ground loop, ground source, ground source heat pump, HAP, Hardy Cross, HASS, hazard, hazard condition, hazen-williams, HCC3, heat, heat exchanger, heat gain, heat loads, heat loss, heat pump, heat transfer, heat transfer multiplier, heating and cooling loads, heating coil, heating loads, HERS, hertz, home energy rating system, hood, hood design, horizontal, hot and chilled water, hot and chilled water analysis, hot and chilled water systems, hot and cold, hot and cold water, hot and cold water pipe sizing, hot and cold water service supply, hot water, hourly, hourly analysis, hourly weather data, HRS Systems, HRS Systems, Inc., HSYM, HTOOLS, hunter, hunter's curve, HVAC, hvac calculation software, hvac calculations, hvac consultant, hvac contractor, hvac design, hvac design software, hvac designer, hvac duct, hvac duct sizing, hvac equipment, hvac estimating, hvac load calculations, hvac loads, hvac operating costs, hvac proposal, hvac sales, hvac selection, hvac software, hvac subcontractor, hvac system, hvac system analysis, hvac system design, hvac tools, hvac utility software, hvac zone, hvac zoning, hvacr, hvacr software, hydratec, hydraulic, hydraulic calculations, hydronic, hydronic system design, I squared t, i2t, IBM PC, IEEE, IES, IGHSPA, indirect water temperature control, indoor lighting, indoor lighting calculations, indoor lighting design, industrial, industrial hygiene, industrial ventilation, infiltration, infiltration loads, INPOINT, insulation, K-factor, kilowatt, kilowatt hours, KRACK, KVA, KWH, LARKIN, leaving coil, leaving coil conditions, LENNOX, LIFE, life cycle, life cycle costing, LIGHT, lighting, load, load calculations, load flow, loads, loop, loop design, loop sizing, loop valves, mail order, mail order sales, manual d, manual j, manual n, masonry chimney, McQuay, air duct, air duct design, air duct design software, air duct electrical plumbing, air duct engineering, air duct system, air duct system design, memate, ductulator, ductulator Design, ductulator Software, metric, metric software, Microworks, minimum melt, monthly and annual, monthly bin, monthly costs, monthly operating costs, motor, motor damage, motor damage curve, motor startup, MUNTERS, National Electric Code, National Fire Protection Association, National Fuel Gas Code, National Plumbing Code, natural gas pipe sizing, nc level, NEC, NEC code, Newton Raphson, NFGC, NFPA, NFPA 13, node, noise attenuation, noise criteria, one line, one line diagram, Only ACCA Approved, Only ACCA Approved Software, operating costs, optimize, optimum, order, Orloff, Orloff Computer, Orloff Computers Services, OSU, outdoor lighting, outdoor lighting design, OUTPOINT, overall heat transfer coefficient, overcurrent, overcurrent device, overcurrent relay, overhead cable, panel, panel design, panel schedule, phase to neutral, phase to phase, Phil Jeffers, diffuser, diffuser analysis, diffuser data, diffuser fittings, pipe loop sizing, diffuser network, diffuser size, diffuser sizing, diffuser system, diffuser system analysis, plumbing, plumbing codes, plumbing design, plumbing design software, plumbing engineering, plumbing engineering software, plumbing pipe sizing, point by point, point by point lighting, power distribution system, Power Tools, Power*Tools, premium, pressure, pressure drop, pressure loss, pretreated air, pretreated outside air, product load, program, proposal, protection, PSYCHART, psychrometric analysis, psychrometric chart, psychrometric chart software, psychrometric software, psychrometrics, pump, pump data, qhvac, quality, quick commercial, quick commercial hvac, quick commercial hvac loads, Quick Quote, Quote, R.E. Michel, radial electric power distribution system, radiator, reactance, rectangular, REFRIG, refrigerant, refrigerant line sizing, refrigeration, refrigeration box, refrigeration box load, refrigeration design software, refrigeration loads, refrigeration software, relay, relay coordination, residential, residential and light commercial, residential energy analysis, residential hvac load calculations, residential load calculations, resistance, Rheem, RHVAC, RIGHT D, RIGHT J, RIGHT LOOP, RIGHT N, RIGHT QUOTE, RIGHT-D, RIGHT-J, RIGHT-LOOP, RIGHT-N, RIGHT-QUOTE, roof, roofing, round, Rudd, Russell, safety, sales, sales and development, sales proposals, sanitary, sanitary building drain, sanitary drain, schedules, secondary loop, hvac system, hvac system value, selection, selective coordination, service entrance, service entrance panel, service supply, service supply diffuser, service supply diffuser sizing, sewer, sheet metal, short circuit, short circuit calculations, simulation, simulation, single line, single line diagram, single phase, SIP, SKM, SKM Captor, SKM Dapper, skylight, slinky, slinky design, slot, slot loss, slot loss factor, SMACNA, Softdesk, software, software sales, software sales and development, software sales tools, sound, sound analysis, SPIPE, SPRINK, sprinkler, sprinkler design, sprinkler design software, SprinklerCalc, Square D, stack, standard 62, static pressure, static regain, structurally insulated panels, supplier, supply air, supply cfm, supply/demand, supply/demand graph, switch, system effect, system effect factor, system simulation, systems, T method, Temp Star, TempStar, tertiary, TETD, TFM, The Trane Company, Tim Frost, Tim Frost Design Services, time amp, time amp curve, time-amp, time-amp curve, ton, tonnage, total clear, total pressure, TRACE, Trane, Trane Air Conditioning, Trane Light Commercial, Trane Unitary, transformer, tree builder, trench, Triathlon, TRON, type B, u factor, u-factor, u-factor calculations, Uniform Plumbing Code, UPC, utility, utility rates, variable air volume, variable speed pump, VAV, VAV box, VDROP, velocity, velocity pressure, vent, vent pipe, vent tables, ventilation, vertical bore, vertical bore hole, voltage drop, voltage transformer, hexagon, hexagon software, hexagon software, waste, waste water, waste water drainage, water, water flow, Water Furnace, water pressure, water supply, water velocity, watt, weather, weather data, Weatherking, wild coil, William Smith, William W. Smith, Windows, Windows 95, Windows Software, WITT, Wright Associates, wrightsoft, X and R data, X/R, X/R ratio, York, York International, York Triathlon, zonal cavity, zone, zone controls, zone system, zoning ACCA, ACCA approved, ACCA manual d, ACCA manual j, ACCA manual n, AE, AEC, A/E/C Energy Design Systems, engineer, engineering, Engineered Software, engineering design software, engineering software, HVAC, hvac calculation software, hvac calculations, hvac consultant, hvac contractor, hvac design, hvac design software, hvac designer, hvac duct, hvac duct sizing, hvac equipment, hvac estimating, hvac load calculations, hvac loads, hvac operating costs, hvac proposal, hvac sales, hvac selection, hvac software, hvac subcontractor, hvac system, hvac system analysis, hvac system design, hvac tools, hvac utility software, hvac zone, hvac zoning, hvacr, hvacr software, fault current, fault current calculations, feeder, feeder sizing, fenestration, fire, fire protection, fire protection design software, fire protection software, fire pump, fire sprinkler, fire sprinkler hydraulic calculations, fire sprinkler hydraulics air duct electrical plumbing, air duct engineering, air duct system, air duct system design, memate, ductulator, ductulator Design, ductulator Software, pipe network, diffuser size, diffuser sizing, diffuser system, diffuser system analysis, plumbing, plumbing codes, plumbing design, plumbing design software, plumbing engineering, plumbing engineering software, plumbing pipe sizing PSYCHART, psychrometric analysis, psychrometric chart, psychrometric chart software, psychrometric software, psychrometrics, REFRIG, refrigerant, refrigerant line sizing, refrigeration, refrigeration box, refrigeration box load, refrigeration design software, refrigeration loads, refrigeration software schedules, secondary loop, hvac system, hvac system value, selection, selective coordination, service entrance, service entrance panel, service supply, service supply pipe, service supply pipe sizing, sewer, sheet metal, short circuit, short circuit calculations, software sales, software sales and development, software sales tools sprinkler, sprinkler design, sprinkler design software, hvac software, hvac software, hvac software, hvac software, hvac software hvac software, hvac software, hvac software, hvac software, hvac software ACCA, ACCA approved, ACCA manual d, ACCA manual j, ACCA manual n, AE, AEC, A/E/C Energy Design Systems, engineer, engineering, Engineered Software, engineering design software, engineering software, HVAC, hvac calculation software, hvac calculations, hvac consultant, hvac contractor, hvac design, hvac design software, hvac designer, hvac duct, hvac duct sizing, hvac equipment, hvac estimating, hvac load calculations, hvac loads, hvac operating costs, hvac proposal, hvac sales, hvac selection, hvac software, hvac subcontractor, hvac system, hvac system analysis, hvac system design, hvac tools, hvac utility software, hvac zone, hvac zoning, hvacr, hvacr software, fault current, fault current calculations, feeder, feeder sizing, fenestration, fire, fire protection, fire protection design software, fire protection software, fire pump, fire sprinkler, fire sprinkler hydraulic calculations, fire sprinkler hydraulics air duct electrical plumbing, air duct engineering, air duct system, air duct system design, memate, ductulator, ductulator Design, ductulator Software, pipe network, pipe size, pipe sizing, pipe system, pipe system analysis, plumbing, plumbing codes, plumbing design, plumbing design software, plumbing engineering, plumbing engineering software, plumbing pipe sizing PSYCHART, psychrometric analysis, psychrometric chart, psychrometric chart software, psychrometric software, psychrometrics, REFRIG, refrigerant, refrigerant line sizing, refrigeration, refrigeration box, refrigeration box load, refrigeration design software, refrigeration loads, refrigeration software schedules, secondary loop, hvac system, hvac system value, selection, selective coordination, service entrance, service entrance panel, service supply, service supply pipe, service supply pipe sizing, sewer, sheet metal, short circuit, short circuit calculations, software sales, software sales and development, software sales tools sprinkler, sprinkler design, sprinkler design software Autocad © Autodesk Captor, Dapper © SKM MeMate HVAC © Energy & air duct Systems Consultants. RIGHT-D, RIGHT-J, RIGHT-LOOP, RIGHT-N, RIGHT-QUOTE © Wrightsoft Corporation All trademarks property of their respective owners.